logo
Do domu > produkty >
AC-DC hipotetyk
>
Professional Dielectric Loss Tester for Transformer Bushing Capacitor Insulation Performance Detection

Professional Dielectric Loss Tester for Transformer Bushing Capacitor Insulation Performance Detection

Szczegóły produktu:
Miejsce pochodzenia: Xi'an, Shaanxi, Chiny
Nazwa handlowa: XZH TEST
Orzecznictwo: ISO,CE
Numer modelu: XHJS1000R
Szczegółowe informacje
Miejsce pochodzenia:
Xi'an, Shaanxi, Chiny
Nazwa handlowa:
XZH TEST
Orzecznictwo:
ISO,CE
Numer modelu:
XHJS1000R
Zakres pomiarowy: tgδ:
0 ~ 100% ± 1% + 0,040%
CX:
15pF<Cx<300nF ±1%+1p 10kV<60nF 1kV<300nF Test CVT<300nF
L:
>20H(2kV) R>10kΩ(2kV) 0,1%
Przełożenie przekładni CVT:
10 ~ 10 000
Rezolucja:
0,01
Podkreślić:

High Light

Podkreślić:

dielectric loss tester for transformers

,

transformer bushing capacitor tester

,

insulation performance tester with warranty

Trading Information
Minimalne zamówienie:
1 jednostka
Cena:
Negocjowalne
Szczegóły pakowania:
opakowania drewniane
Czas dostawy:
5-8 dni roboczych
Zasady płatności:
T/T
Możliwość Supply:
2000 jednostek/rok
Opis produktu
Product Overview

XHJS1000R Dielectric Loss Tester applies digital notch technology to shield the test from power frequency electric field interference, which effectively addresses the challenge of precise measurement in strong electric field interference environments. The tester is compatible with generator power supply, and when matched with an oil cup and temperature control unit, it can conduct dielectric loss testing of insulating oil.

Performance Features
  • Integrated with built-in power supply, step-up transformer and standard capacitor;
  • Support for positive/reverse connection mode, internal/external standard capacitors, internal/external test voltage and self-excitation testing method;
  • Realize fully automatic detection of inductance, capacitance and resistance, with real-time angle display function;
  • Possess multiple protective mechanisms for input voltage fluctuation, high-voltage current, output short circuit, power fault, overvoltage, overcurrent, temperature abnormality, etc.
Technical Parameters
  • Measurement range: tgδ: 0~100% ±1%+0.040% Cx:15pF<Cx<300nF ±1%+1p 10kV<60nF 1kV<300nF CVT test<300nF
  • L:>20H(2kV) R>10kΩ(2kV) 0.1%
  • CVT transformation ratio Precision: 0.1% Resolution: 0.01
  • Insulation resistance: Error below 5% at 100kΩ-1000GΩ(250V) Error of 10% at 100GΩ-1000GΩ(10000V)
  • High-voltage output: 0.5KV~10KV/200mA ±2%
  • Service conditions: -15℃~40℃ Rh<80%
  • Working power supply: AC 220V±10%, generator power supply is permissible